The Impact of Using Electrochromic on the Cooling Load in Offices at Hot and Dry, Hot and Humid, and Cold Climates in Iran

Authors

Abstract

Reducing building energy consumption is one of the sustainable architecture principles. Since nearly half of consumed energy in the buildings is lost through windows, many studies have been conducted to find solutions for energy conservation and solar radiation control. Application of electrochromic smart glass is one of those solutions. In order to have optimum building selection, the evaluation of the effectiveness of this type of glasses in various climates in Iran is necessary. So far no research has been conducted on this issue. In the present study, the effect of using electrochromic smart glass on the cooling load of an office building is investigated in three cities of Bushehr (with hot-humid climate), Shiraz (with hot-dry climate), and Tabriz (with cold climate). For this purpose, a three-storey office building is simulated in Design Builder software and the annual cooling load of the building is calculated in three modes with 6mm plain glass, double-glazed glass and electrochromic smart glass. The results show that in Bushehr, Shiraz, and Tabriz, the application of electrochromic glass has a significant effect on the reduction of cooling load and, thus, is appropriate. In Bushehr, the application of electrochromic glass has reduced the cooling load of the building by 19% and 8% compared with the ordinary glass and the double-glazed one, respectively. In Shiraz and Tabriz, the cooling load also decreases by 28% and 10%. These results show that the efficiency of electrochromic glass in hot-dry and cold climate is higher than hot-humid climate.

Keywords


[1] Nasrollahi, F., Green Office Buildings: Low Energy Demand Through Architectural Energy Efficiency, Young Cities Research Paper series, Vol. 8, Berlin University, 2013. [2] Granqvist, C.G., "Electrochromics and Thermochromics: Towards a New Paradigm for Energy Efficient Buildings", Materialstoday Proceeding, pp. 2–11, 2016. [3] Pérez-Lombard, L., Ortiz, J. and Pout, C., "A Review on Buildings Energy Consumption Information", Energy and Building, Vol. 40, No. 3, pp. 394–398, 2008. [4] Daqiqeh, S., Shannigrahi, S. and Ramakrishna, S., "A Review of Conventional, Advanced, and Smart Glazing Technologies and Materials for Improving Indoor Environment", Solar Energy Materials and Solar Cells, Vol. 159, pp. 26–51, 2017. [5] DeForest, N., Shehabi, A., O’Donnell, J., Garcia, G., Greenblatt, J., Lee, E. S., Selkowitz, S. and Milliron, D. J., "United States Energy and CO2 Savings Potential From Deployment of Near-Infrared Electrochromic Window Glazings", Building and Environment, Vol. 89, pp. 107–117, 2015. [6] Piccolo, A. and Simone, F., "Performance Requirements for Electrochromic Smart Window", Journal of Building Energy, Vol. 3, pp. 94–103, 2015. [7] Wen, R., Arvizu, M. A., Niklasson, G. A. and Granqvist, C. G., "Electrochromic for Energy Efficient Buildings: Towards Long-Term Durability and Materials Rejuvenation", Surface Coating Technology, Vol. 278, pp. 121–125, 2015. [8] Granqvist, C. G., "Recent Progress in Thermochromics and Electrochromics: A Brief Survey", Thin Solid Films, Vol. 614, pp. 90–96, 2016. [9] Tavares, P., Bernardo, H., Gaspar, A. and Martins, A., "Control Criteria of Electrochromic Glasses for Energy Savings in Mediterranean Buildings Refurbishment", Solar Energy, Vol. 134, pp. 236–250, 2016. [10] Gugliermetti, F. and Bisegna, F., "Visual and Energy Management of Electrochromic Windows in Mediterranean Climate", Building and Environment, Vol. 38, pp. 479–492, 2003. [11] Nilsson, A. M. and Roos, A., "Evaluation of Optical and Thermal Properties of Coatings for Energy Efficient Windows", Thin Solid Films, Vol. 517, No. 10, pp. 3173–3177, 2009. [12] Purushothaman, K. K., Antony, S. J. and Muralidharan, G., "Optical, Structural and Electrochromic Properties of Nickel Oxide Films Produced by Sol – Gel Technique", Solar Energy, Vol. 85, No. 5, pp. 978–984, 2011. [13] Piccolo, A., Pennisi, A. and Simone, F., "Daylighting Performance of an Electrochromic Window in A Small Scale Test-Cell", Solar Energy, Vol. 83, No. 6, pp. 832–844, 2009. [14] Deb, S. K., Lee, S., Tracy, C. E., Pitts, J. R., Gregg, B. A. and Branz, H. M., "Stand-Alone Photovoltaic-Powered Electrochromic Smart Window", Electrochimca Acta, Vol. 46, pp. 2125–2130, 2001. [15] Deforest, N., Shehabi, A., Selkowitz, S. and Milliron, D. J., "A Comparative Energy Analysis of Three Electrochromic Glazing Technologies in Commercial and Residential Buildings", Applied Energy, Vol. 192, pp. 95–109, 2017. [16] Granqvist, C. G., "Electrochromics for Smart Windows: Oxide-based Thin Films and Devices", Thin Solid Films, Vol. 564, pp. 1–38, 2014. [17] Zinzi, M., "Office Worker Preferences of Electrochromic Windows: A Pilot Study", Building and Environment., Vol. 41, pp. 1262–1273, 2006. [18] Piccolo, A. and Simone, F., "Effect of Switchable Glazing on Discomfort Glare From Windows", Building and Environment, Vol. 44, No. 6, pp. 1171–1180, 2009. [19] Sbar, N. L., Podbelski, L., Mo, H. and Pease, B., "Electrochromic Dynamic Windows for Office Buildings", International Journal of Sustainable Built Environment., Vol. 1, No. 1, pp. 125–139, 2012. [20] Shaeri, J. and Shaeri, Z., "The Use of Smart Glass in Building Design with a Sustainable Architecture Approach", The 2nd National Conference on Architecture, Restoration, Urbanism and Sustainable Environment, 2014. (in Persian) [21] Piccolo, A., "Thermal Performance of an Electrochromic Smart Window Tested in an Environmental Test Cell", Energy and Building, Vol. 42, No. 9, pp. 1409–1417, 2010.