Abstract

In the light of the emergence of smart grids, the functions associated with this type of grids in the blocks of the energy management system require the adoption of robust strategies in order to provide a higher level of control and protection. Under-frequency load shedding (UFLS) sheds load blocks when the frequency drop is below the threshold limit. In adaptive UFLS, in an advanced telecommunications platform, the main quantities of the system are measured at each hour and in real-time; besides, the optimal amount of load is shed according to frequency deviation. In this paper, an hourly framework using Mixed-Integer Linear Programming (MILP) is proposed for an optimal design of an adaptive UFLS in smart networks. The goal is to provide a more systematic adaptive UFLS that is less dependent on trial and error. Here, the under-frequency relay is set for each hour in regard to operating conditions and uncertainties resulting from contingencies, to renewable energy sourses (RES), and to load fluctuations at that hour. The simulations are performed on the IEEE 39-bus test system over a 24-hour time horizon.

Keywords


[1] Laghari, JA., Mokhlis, H., Karimi, M., Bakar, AHA. and Mohamad, H., "A new under-frequency load shedding technique based on combination of fixed and random priority of loads for smart grid applications", IEEE Transactions on Power Systems, Vol. 30, No. 5, pp. 2507-2515, 2015. [2] Tabandeh, A., Abdollahi, A. and Rashidinejad, M. "Reliability constrained congestion management with uncertain negawatt demand response firms considering repairable advanced metering infrastructures", Energy, Vol. 104, pp. 213-228, 2016. [3] Rudez, U. and Mihalic, R., "WAMS-based underfrequency load shedding with short-term frequency prediction", IEEE Transactions on Power Delivery, Vol. 31, No. 4, pp. 1912-1920, 2016. [4] Rudez, U. and Mihalic, R., "Monitoring the first frequency derivative to improve adaptive underfrequency load-shedding schemes", IEEE Transactions on Power Systems, Vol. 26, No. 2, pp. 839-846, 2011. [5] Abdelwahid, S., Babiker, A., Eltom, A. and Kobet, G., "Hardware implementation of an automatic adaptive centralized underfrequency load shedding scheme", IEEE Transactions on Power Delivery, Vol. 29, No. 6, pp. 2664-2673, 2014. [6] Xia, N., Gooi, HB., Abur, A., Chen, SX., Eddy, YSF. and Hu W., "Enhanced state estimator incorporating adaptive underfrequency load shedding under contingencies via the alternating optimization method", Electrical Power and Energy Systems, Vol. 81, pp. 239–247, 2016. [7] Santos, AQ., Monaro, RM., Coury, DW. and Oleskovicz, M., "A new real-time multi-agent system for under frequency load shedding in a smart grid context", Electric Power Systems Research, Vol. 174, 105851, 2019. [8] Talaat, M., Yatata, AY., Alsayyari, AS. and Alblawi, A., "A smart load management system based on the grasshopper optimization algorithm using the under-frequency load shedding approach", Energy, Vol. 190, 116423, 2020. [9] Aparicio, N., Villalba, SA., Belenguer, E., Gimenez, RB., "Automatic under-frequency load shedding mal-operation in power systems with high wind power penetration", Mathematics and Computers in Simulation, Vol. 146, pp. 200-209, 2018. [10] Gu, W., Liu, W., Zhu, J., Zhao, B., Wu, Z., Luo, Z. and Yu, J., "Adaptive decentralized under-frequency load shedding for islanded smart distribution networks", IEEE Transactions on Sustainable Energy, Vol. 5, No. 3, pp. 886-895, 2014. [11] Li, H., Wang, J., Du, Z., Zhao, F., Liang, H. and Zhou, B., "Frequency control framework of power system with high wind penetration considering demand response and energy storage", The Journal of Engineering, Vol. 13, pp. 1153-1158, 2017. [12] He, P., Wen, B. and Wang, H., "Decentralized adaptive under frequency load shedding scheme based on load information", IEEE Access, Vol. 7, pp. 52007-52014, 2019. [13] Banijamali, SS. and Amraee, T., "Semi-adaptive setting of under frequency load shedding relays considering credible generation outage scenarios", IEEE Transactions on Power Delivery, Vol. 34, pp. 1098–1108, 2019. [14] Shekari, T., Gholami, A. and Aminifar, F. Sanaye-Pasand, "An adaptive wide-area load shedding scheme incorporating power system real-time limitations", IEEE Systems Journal, Vol. 12, pp. 759-767, 2018. [15] Atighechi, H., Hu, P., Ebrahimi, S., Lu, J., Wang, G. and Wang, L., "An effective load shedding remedial action scheme considering wind farms generation", International Journal of Electrical Power and Energy Systems, Vol. 95, pp. 353–363, 2018. [16] Amraee, T., Darenaghi, MG., Soroudi, A. and Keane, A., "Probabilistic under frequency load shedding considering RoCoF relays of distributed generators", IEEE Transactions on Power Systems, Vol. 33, pp. 3587-3598, 2018. [17] Darebaghi, MG. and Amraee, A., "Dynamic multistage under frequency load shedding considering uncertainty of generation loss", IET Generation, Transmission, Distribution, Vol. 11, pp. 3202-3209, 2017. [18] Zhenglong, S., Guowei, C., Yuwei, W. and Jiarong, S., "A method for the design of UFLS schemes of regional power system using improved frequency response model", International Transactions on Electrical Energy Systems, Vol. 2365, pp. 1-11, 2017. [19] Ketabi, A. and Fini, MH., "Adaptive under frequency load shedding using particle swarm optimization algorithm", Journal of Applied Research and Technology, Vol. 15, pp. 54-60, 2017. [20] Moazzami, M., Khodabakhshian, A. and Hooshmand, RA., "A new optimal under-frequency load-shedding method using hybrid culture–particle swarm optimization–co-evolutionary algorithm and artificial neural networks", Electric Power Components and Systems, Vol. 43, pp. 69–82, 2015. [21] Gomez, C., Qadri, SS. and Galiana, F., "Under-frequency load shedding via integer programming", IEEE Transactions on Power Systems, Vol. 27, PP. 1387–1394, 2012. [22] Rudez, U. and Mihalic, R., "Predictive underfrequency load shedding scheme for islanded power systems with renewable generation", Electric Power Systems Research, Vol. 126, pp. 21-28, 2015. [23] Wu, L., Shahidehpour, M. and Li, T., "Cost of reliability analysis based on stochastic unit commitment", IEEE Transactions on Power Systems, Vol. 23, No. 3, pp. 1364-1374, 2008. [24] Amjadi, N., Aghaei, J. and Shayanfar, H. A., "Stochastic multiobjective market clearing of joint energy and reserves auctions ensuring power system security", IEEE Transactions on Power Systems, Vol. 24, No. 4, pp. 1841-1854, 2009. [25] Rezaei, N. and Kalantar, M., "Stochastic frequency-security constrained energy and reserve management of an inverter interfaced islanded microgrid considering demand response programs", International Journal of Electrical Power and Energy Systems, Vol. 69, pp. 273-286, 2015. [26] Rezaei, N. and Kalantar, M., "Hierarchical energy and frequency security pricing in a smart microgrid: An equilibrium inspired epsilon constraint based multi-objective decision making approach", Energy Conversion and Management, Vol. 98, pp. 533-543, 2015. [27] Rezaei, N. and Kalantar, M., "Smart microgrid hierarchical frequency control ancillary service provision based on virtual inertia concept: An integrated demand response and droop controlled distributed generation framework", Energy Conversion and Management, Vol. 92, pp. 287-301, 2015. [28] Kundur, P., Balu, N. and Lauby, M. Power System Stability and Control, 7th ed. New York: McGraw-Hill, Inc., 1994. [29] Rezaei, N. and Kalantar, M., "Economic–environmental hierarchical frequency management of a droop-controlled islanded microgrid", Energy Conversion and Management, Vol. 88, pp. 498–515, 2014. [30] Pai, A., Energy function analysis for power system stability, Springer Science & Business Media, 2012. [31] U.S. Energy Information Administration, 1000 Independence Ave., SW, Washington, DC 20585, U.S. Energy Information Administration, 1000 Independence Ave., SW, Washington, DC 20585. https://www.eia.gov/dashboard/newengland/overview [32] Vatani, M., Amraee, T., Ranjbar, and Mozaffari, B., "Multi-Stage under frequency load shedding relay in islanded distribution systems", JEM. Vol. 7, No. 4, pp. 2-11, 2018. [33] Abrisham Foroushan Asl, S., Gandomkar, M. and Nikoukar, J., "System stability-constrainted optimal protection coordination in the microgrid including renewable energy sources and energy storage" JEM. Vol.11, No. 2, pp. 16-31, 2021. [34] Nguyen, T. A., Crow, M. L. and Elmore, A. C., "Optimal sizing of a vanadium redox battery system for microgrid systems", IEEE transactions on sustainable energy, Vol. 6, No. 3, pp.729-737, 2015. [35] Lan, H., Wen, S., Hong, Y. Y., David, C. Y. and Zhang, L., "Optimal sizing of hybrid PV/diesel/battery in ship power system", Applied energy, Vol. 158, pp. 26-34, 2015.